Excessive concrete moisture is a very common problem that can result in significant delays, additional cost, and eventually a damaged floor. It is has resulted in billions of dollars of repair costs.

WHY TEST?

  • To protect the owner from potential failures and losing use of the area.
  • To meet the manufacturer’s specifications that require it.

HOW TO TEST?

  • ASTM F-1869 Calcium Chloride test (concern - will not accurately measure the long-term moisture condition of the concrete slab)
  • ASTM F-2170 Relative Humidity (RH) testing  (does indicate moisture that will actually come in contact with the flooring after it is installed; the best choice for monitoring drying concrete and managing a project)

MOISTURE SOLUTIONS - We offer a range of methods—each situation requires a different solution depending on the site conditions, environmental conditions, severity of the issue and the owner’s circumstances.

Download Starlog Concrete Moisture PDF

Download Moisture Emission Testing Whitepaper PDF